Carbon Steel and Type 304 stainless steel samples were exposed in thirteen corrosion tests conducted in solutions (with varying pH, oxygen content, SO2 content, and chloride ion content) in a simulated sour water solution produced in the laboratory. Corrosion rates were calculated, and U-bends were examined for stress-corrosion cracking.
|