reports
Home Reports Material Evaluation Corrosion ...

Corrosion Evaluation of Carbon Steel in Lithium Bromide Solutions


Corrosion tests conducted in inhibited 60% LiBr indicate that liquid phase corrosion rates remain low even up to 350 F. However, vapor phase and liquid-vapor interface corrosion rates are such that carbon steel will require protection above 300 F. 70-30 cupro-nickel showed low corrosion rates with no pitting at all temperatures tested. Grade 2 titanium showed significant pitting at all temperatures tested. Grade 7 titanium showed significant pitting at 300 F and above. Fluoroshield, a fluorocarbon polymer coating, performed well in these tests and appears to be a viable method for protecting carbon steel in LiBr environments.

This report is available for download to corporate users only at this time and will be soon made available for individual purchase.
 
 
Category Index Top